How we picked: these picks come from manufacturer specifications, forum discussions of each meter and other published guides. We have not used or tested these tools. How we make recommendations.
No single meter suits every electrician. The right one depends on where you work in the system, the loads you measure and whether you need extras like temperature or logging. Each pick below is matched to one kind of work, with the reason and the sources.
A note on sources. The electrician trade forums we tried would not let our research tools read them. The forum threads used here are on EEVblog, an electronics forum, and Garage Journal, a general workshop forum. Most posters there are not electricians, and we say so where it matters.
Best for everyday residential and light-commercial work
Fluke 117 Electrician’s Multimeter
Why it is our pick: Fluke says the 117 is designed for electricians. It is true RMS and combines built-in non-contact voltage detection, a low impedance mode against ghost voltage and automatic AC/DC selection in a compact meter (Fluke).
On the EEVblog forum, posters advising an industrial technician pointed to its small size and one-hand use. HomeGrail names it its general-purpose Fluke pick. Bob Vila tested it as part of a kit with a clamp meter and liked the non-contact tester.
Limits and disagreements: one EEVblog poster questioned whether CAT III 600V is enough for 480 V systems (thread). Posters in another EEVblog thread note it has no mA range, and a Garage Journal poster asked whether its CAT III 600V rating and lack of mA and µA ranges were deal breakers (thread). Bob Vila notes it has no temperature function.
Not the best fit for: Work at service entrances, utility connections or outdoor conductors (CAT IV locations), or 1000 V systems. The 117 is rated CAT III 600V.
Key specifications
Safety rating
CAT III 600V
Maximum voltage between any terminal and earth ground
Why it is our pick: the 87V is rated CAT III 1000 V and CAT IV 600 V, has a low-pass filter for measurements on variable frequency drives, takes temperature with the included probe, and carries a lifetime warranty (Fluke).
On Garage Journal, a self-described electrician keeps an 87V for monitoring and more advanced work. A poster with an industrial maintenance background in another thread says he needed its higher voltage capability. A machine-tool maintenance poster reports that it reads drive output voltage more accurately than a 179 (thread).
Limits and disagreements: the same machine-tool poster calls it too much meter for most maintenance staff, and another Garage Journal poster calls its feature set dated, though proven. HomeGrail found the leads stiff, missed a manual and case, and ranked it below Fluke’s 88V. Fluke’s 87V page gives a 1 meter drop in its specification table and a 3 meter drop test in its comparison table.
Not the best fit for: Buyers who want low impedance mode or built-in non-contact detection (Fluke’s 87V page lists neither), or anyone who mostly needs basic voltage and continuity checks.
Key specifications
Safety rating
EN 61010–1 to 1000 V CAT III, 600V CAT IV
Maximum voltage (AC and DC)
1000 V
Maximum amps (AC and DC)
10 A (20 A for 30 seconds maximum)
Maximum resistance
50 MΩ
Maximum capacitance
9,999 µF
Maximum frequency
200 kHz
Temperature measurement
-200.0 °C to 1090 °C
Low-pass filter
Supports accurate measurements on VFDs using a low-pass filter
Best for commercial work that needs CAT IV and temperature
Fluke 179 True-RMS Digital Multimeter
Why it is our pick: the 179 has the same CAT III 1000 V and CAT IV 600 V rating as the 87V, reads temperature with the included probe, and carries a lifetime warranty (Fluke). Fluke’s 179 page does not list a low-pass filter, which is what separates it from the 87V for drive work.
A machine-tool maintenance poster on Garage Journal used a 179 for years. HomeGrail’s review points to its durability and lifetime warranty.
Limits and disagreements: the Garage Journal poster says the 179 read a drive’s output higher than an 87V-class meter. HomeGrail notes the backlight shortens battery life. Fluke’s 179 page gives maximum capacitance as 10,000 µF in its specification table and 9,999 µF in its comparison table; the card uses the specification table.
Not the best fit for: Measurements in microamps (posters on EEVblog note the 170 series reads A and mA but not µA), or work on drive outputs, where a meter with a low-pass filter is the better match.
Key specifications
Safety rating
EN 61010–1 to 1000 V CAT III; EN 61010–1 to 600 V CAT IV
Why it is our pick: Fluke describes the 115 as a compact true-RMS meter for field service, and the 117 as the version designed for electricians (Fluke’s 115 and 117 comparison). If you do not need the 117’s extras, the 115 covers the same core measurements (Fluke 115).
On Garage Journal, a poster calls the 115 an excellent choice for home use unless you need temperature or extra resolution. HomeGrail includes it in its Fluke picks as compact and capable.
Limits and disagreements: HomeGrail found the dial did not always click firmly into position. The 115 has a 3-year warranty, against lifetime on the 87V, a point raised in the same Garage Journal thread. In another Garage Journal thread, a buyer comparing the two chose the 117.
Not the best fit for: Electricians who want built-in non-contact voltage detection and low impedance mode. Fluke says those are what the 117 adds. Also not for CAT IV work.
Key specifications
Safety rating
CAT III 600V
Maximum voltage between any terminal and earth ground
Why it is our pick: the 289 stores logged readings with a time stamp, has low impedance mode and a low-pass filter, and carries a limited lifetime warranty (Fluke). That makes it a tool for faults that come and go, where you leave the meter recording.
Posters on the EEVblog forum rate its logging and accuracy. In a second thread, one owner says he bought it only because a job required logging.
Limits and disagreements: owners in both threads report a low-contrast display, short battery life and slow response. Fluke’s 289 page does not state a safety category rating, so confirm the rating with Fluke before using it on a given circuit. The page also gives two figures for stored events (10,000 in its overview, 15,000 in its feature list).
Not the best fit for: Everyday carry on residential and commercial jobs. Owners describe it as slow, hard to read and heavy on batteries.
Key specifications
Maximum voltage between any terminal and earth ground
1000 V
Current
Measures up to 10 A (20 A for 30 seconds)
Resistance, top range
500.0 MΩ
Capacitance
Provides up to 100 mF capacitance range
Frequency, top range
999.99 kHz
Temperature (excluding probe)
-200.0°C to 1350.0°C (-328.0°F to 2462.0°F)
Low impedance
LoZ Volts, a low impedance voltage function for eliminating ghost voltages
Low-pass filter
low pass filter for accurate voltage and frequency measurements
Logging
Stores up to 15,000 recorded events
Display
50,000 count, 1/4 VGA dot matrix display with white backlight
Why it is our pick: Klein rates the MM720 CAT IV 600V and CAT III 1000V. It is true RMS, has low impedance mode, reads temperature, and Klein states a 2 m drop rating and IP42 (Klein Tools).
On Garage Journal, an MM720 owner notes its auto-brightness display has a manual low-brightness mode. On the EEVblog forum, a mechanic shortlisted it as a known-brand option outside Fluke.
Limits and disagreements: the same Garage Journal thread reports that a related Klein meter with the same display type drained batteries quickly, and the EEVblog poster found few reviews and the same battery worry. Treat this as the least-sourced pick on the page.
Not the best fit for: Buyers who want a long record of owner reports. We found little in-depth discussion of this meter. Klein’s page also does not state the warranty term.
CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Specifications compared
Every value below is copied from the manufacturer’s page for that model. Where the page does not state a value, the table says so. Manufacturers word their specifications differently, so check the product page before comparing two figures directly.
Fluke’s 117 page lists a temperature range in its comparison table but not in its own specifications or description, and Bob Vila says the 117 has no temperature function. We treat it as having none.
Whether the 87V is the right industrial meter: Garage Journal posters with industrial backgrounds rely on it, one calls it too much meter for most maintenance staff, and HomeGrail ranks it below the 88V.
Whether CAT III 600V is enough: Fluke’s safety guide says a 480 V feeder panel needs at least CAT III 600 V, while one EEVblog poster would want more margin on 480 V systems. Check your meter against the work you do.